18/2 Fire Alarm Riser FPLR Solid Bare Copper Cable – 1000ft – Red
SKU: SKU: TS-FPLR-18/2-RD
💡 Pro Tip:
Order 4+ boxes and save 11%
Order 14+ boxes and save 14%
Order 36+ boxes and save 16%
FREE Shipping on Even 1 Box
Couldn't load pickup availability
Notify me when it's back in stock
Please indicate that you have read and agree to the Privacy Policy before submitting your data.
We will notify you when this product is available again. Your email address will not be shared with anyone else.
Thank you for subscribing.

Est. Delivery From KS

Est. Delivery From CA

Est. Delivery From MD

- Description
About 18/2 Fire Alarm Riser
18/2 Fire Alarm Riser cables are used in vertical fire alarm pathways inside buildings. They are built to support signal continuity between floors while meeting fire safety codes for riser spaces.
This cable type is commonly installed in stairwells, shafts, and wall cavities where controlled flame spread is required. An 18/2 Fire Alarm Riser setup helps ensure alarms communicate clearly across multiple levels during emergency conditions.
Key Features
Riser-Rated Jacket
The cable jacket is approved for vertical installations. It helps limit flame spread between floors.
Dual-Conductor Design
An 18/2 configuration includes two insulated conductors. This supports dependable fire alarm signaling.
Code-Compliant Construction
18/2 Fire Alarm Riser cables meet building safety standards. They are suitable for commercial and residential systems.
Consistent Signal Transmission
The cable supports stable alarm communication. It helps reduce signal interruption during operation.
Various Types
Solid Conductor Fire Alarm Riser
Solid conductor versions are used in permanent runs. They provide reliable performance in fixed installations.
Stranded Fire Alarm Riser Cable
Stranded designs allow easier handling during pulls. They are useful in complex routing paths.
Shielded Fire Alarm Riser Cable )
Shielded options reduce interference from nearby wiring. They help maintain signal clarity in busy cable spaces.
Best Use Cases
Multi-Story Buildings
18/2 Fire Alarm Riser cables are ideal for vertical runs. They support alarm communication between floors.
Stairwells and Shafts
These areas require riser-rated fire alarm wiring. The cable meets safety and installation requirements.
Commercial Fire Alarm Systems )
Used in offices, schools, and retail buildings. They help maintain dependable alarm operation.
Support code-compliant fire alarm installations with 18/2 Fire Alarm Riser cables built for reliable vertical signal transmission.
Specification:
|
Feature |
Value / Spec |
Standards Compliance |
Professional Notes |
|
Conductor Count |
2 Conductors |
NEC Article 760 |
Color-coded Red (+) and Black (-) for polarity. |
|
Wire Gauge |
18 AWG |
ASTM B3 |
Smaller gauge than 16/2; easier to pull and terminate. |
|
Jacket Rating |
FPLR (Riser Rated) |
UL 1424 / UL 1666 |
Tested for vertical flame spread in shafts. |
|
Conductor Type |
Solid Bare Copper |
NFPA 72 |
Solid copper is mandatory to prevent signal fatigue. |
|
Voltage Rating |
300 Volts |
UL Standard |
Suitable for low-voltage fire protective circuits. |
|
Color |
Red Jacket |
Industry Standard |
Bright red identifies the circuit as "Fire Life Safety." |
|
Common Uses |
SLC Loops / Strobes |
RoHS Compliant |
Standard for addressable loops and local detectors. |